home *** CD-ROM | disk | FTP | other *** search
/ Belgian Amiga Club - ADF Collection / BS1 part 34.zip / BS1 part 34 / Maxiplan III 3.5.adf / MP3 / PlanHelp / options.help < prev    next >
Text File  |  1990-01-05  |  7KB  |  169 lines

  1. ---------------------------------------------------------------------
  2. OPTIONS MENU HELP
  3. ---------------------------------------------------------------------
  4.  
  5. The Options menu allows you to choose certain options
  6. relating to video and audio display of the Worksheet and its
  7. contents.
  8.  
  9. --------------------------------------------------------------------
  10. Show                                              
  11. --------------------------------------------------------------------
  12.  
  13. Allows you to either display formulas or the formula's value as the
  14. contents of a Worksheet cell.
  15.  
  16. Default option is Value
  17.  
  18. --------------------------------------------------------------------
  19. Cell Note Output/Display                          
  20. --------------------------------------------------------------------
  21.  
  22. A Cell Note for the active cell is displayed by pressing the HELP
  23. Key.  Three options are available for Cell Note output:
  24.  
  25.      *  Text Only - displayed in a Requester with an OK button
  26.      *  Speech Only - output via the Amiga's voice facility
  27.      *  Both Text and Speech
  28.  
  29. Default option is Text Only.
  30.  
  31. --------------------------------------------------------------------
  32. Wordstar Keys                                     
  33. --------------------------------------------------------------------
  34.  
  35. If the Wordstar Keys option is on, you can move the Active Cell by 
  36. using the following control keys:
  37.  
  38.           Key                 Action
  39.        Control  with X     Move Active Cell DOWN
  40.        Control  with S     Move Active Cell LEFT
  41.        Control  with D     Move Active Cell RIGHT
  42.        Control  with E     Move Active Cell UP
  43.  
  44. --------------------------------------------------------------------
  45. Protection                                        
  46. --------------------------------------------------------------------
  47.  
  48. When the Protection is Enabled, all cells formatted as Protected
  49. under the Format Menu will not allow you to alter their contents.
  50. When Protection is Disabled, all Cells may be changed regardless
  51. of their protection formatting.
  52.  
  53. Default option is Off.
  54.  
  55. --------------------------------------------------------------------
  56. Freeze Titles                                     
  57. --------------------------------------------------------------------
  58.  
  59. Freeze Titles allows you to scroll throughout the Worksheet while
  60. leaving any number of Row and Column labels or data in view for
  61. easy identification.  Freeze Titles has four options:
  62.  
  63. *  None - no freezing of Rows or Columns
  64. *  Horizontal - all Rows above the site of Freezing remain
  65.    displayed when vertical scrolling is enabled
  66. *  Vertical - all Columns to the left of the site of Freezing
  67.     remain displayed when horizontal scrolling used
  68. *  Both - all Rows above and Columns to the left of Active Cell 
  69.    remain displayed when window is scrolled in either direction.
  70.  
  71.    Default option is None. 
  72.    
  73.    To freeze rows & columns select a range consisting of the rows
  74.    and/or columns you wish to freeze.  Then select one of the submenu
  75.    items described above.
  76.  
  77. --------------------------------------------------------------------
  78. Outline Level
  79. --------------------------------------------------------------------
  80.  
  81. Outline level selects the levels of outline desired to a selected
  82. range of rows.
  83.  
  84. ---------------------------------------------------------------------
  85. Outline Display
  86. ---------------------------------------------------------------------
  87.  
  88. After outline level has been set, you can exclude those rows from view
  89. and printing by setting the outline display to a level which hides
  90. those lines from view.
  91.  
  92. --------------------------------------------------------------------
  93. Keyboard Echo                                     
  94. --------------------------------------------------------------------
  95.  
  96. When Keyboard Echo is ON, all keystrokes are spoken via the Amiga's
  97.  
  98. voice facility as they are keyed in.
  99.  
  100. Default option is OFF.
  101.  
  102. ---------------------------------------------------------------------
  103. Display Grid                                      
  104. ---------------------------------------------------------------------
  105.  
  106. If Display Grid is turned on, a grid of horizontal and vertical grid
  107. lines will be displayed in the Worksheet window.
  108.  
  109. Default option is OFF.
  110.  
  111. ---------------------------------------------------------------------
  112. Return Key                                        
  113. ---------------------------------------------------------------------
  114.  
  115. Controls the movement direction of the Active Cell when the Return
  116.  Key is pressed.  Three options are available:
  117.  
  118. *  Doesn't Move - No movement of the Active Cell 
  119. *  Move Down - Moves down one Row
  120. *  Move Right - Moves over one Column
  121.  
  122. Default option is Move Down.
  123.  
  124. ---------------------------------------------------------------------
  125. Calc Order                                        
  126. ---------------------------------------------------------------------
  127.  
  128. Determines the order that MaxiPlan evaluates cells during a
  129. recalculation.  Three options are available:
  130.  
  131. *  Natural - in order referred to by Formulas
  132. *  Row by Row - evaluates across first Row, then second Row, etc.
  133. *  Column by Column - evaluates down first Column, then second
  134.    Column, etc.
  135.  
  136. Default option is Natural.
  137.  
  138. Note: When automatic recalculation is on, MaxiPlan evaluates
  139. only the minimum number of cells necessary when you enter data.
  140. In order to use the order selected by this menu item you must be
  141. in manual recalculation mode and use the F1 key to recalc the
  142. worksheet.
  143.  
  144. --------------------------------------------------------------------
  145. Set Password                                      
  146. --------------------------------------------------------------------
  147.  
  148. Displays a Requester for keying in a Password.  Only one Password
  149. can be specified per Worksheet.  A Cell must be formatted with
  150. Password from the Format Menu.  When the Worksheet is saved, closed,
  151. and then reopened, the Cells formatted with Password are hidden
  152.  by --------.  To reveal these Cells, the Worksheet user must access
  153. the Set Password command and key in the correct Password in order
  154. for the cell's contents to be displayed.  These same Cells will
  155. also be formatted for Protection.  Thus to alter their contents,
  156. Protection must be disabled on the Options Menu.
  157.  
  158. Default option is OFF.
  159.  
  160. --------------------------------------------------------------------
  161. Set Currency                                      
  162. --------------------------------------------------------------------
  163.  
  164. Displays Requester to specify both a leading and a trailing currency
  165. symbol.  To display data as currency, the range of cells must be
  166. formatted with Currency under the Format Menu.
  167.    
  168.  
  169.